| Why can't I see pricing for your products? |
| You must create an account or login to view pricing on our site. |
| Rail Installation |
How high of a building can I use a False Car Set for rail installation?
The Wurtec False Car utilizes a Wire Rope Climber Hoist, this hoist will travel whatever the length of cable the is hung from it. The hoist utilizes two wire ropes, one for climbing and the other as an a safety back up. The Wurtec False Cars were used for the new WTC in NYC as well as the Burj Dubai (Khalifa) and other major towers around the world. There is no limit to the travel height of the False-Car due to the design of the cable climbing motor used. |
What is a better method for rail installation, the Wurtec False Car or standard scaffolding? |
| Depending on the height of the building, in a construction project that is less than 5 – 7 floors, scaffolding may be the better option due to the lower travel height. However, anything above 5-7 floors requires a significant amount of time, labor, and materials to install scaffolding. A complete Wurtec False-Car on the other hand, generally installs and is completely rigged up in half a day, thereby greatly reducing the cost to prepare your site and field staff to begin installing rails and other hoistway equipment. |
| Communications |
| FAQs about the S3 Communicator – Note: The S3 Communicator requires an analog telephone line. The digital line must be ran through an analog port and must have at least 24VDC on the telephone line to work properly. |
My keypad is not working on my S3 Communicator, what can I do?
|
| The push button uses the telephone line voltage as its energy source. Check your telephone line connection on the phone and also do a phone line diagnostic by pressing the key on the keypad (be sure you have a 9V battery connected to the phone or the external power connected to the phone to energize the keypad). Also, be sure the push button is plugged into PBA on the circuit board. |
| I keep getting an error message that says “Telephone Line Failure”, but my phone line is working fine, what is the problem? |
| Wurtec supplies a 12VAC isolation transformer with the phone. This transformer should be used with the phone. If you are getting a power source directly from the controller, it can create a ground loop with the telephone line and cause the pone to malfunction. External building power is only needed if you are line sharing the phone. If you ARE line sharing, use the supplied transformer. If you are NOT line sharing, simply disconnect the external power and be sure you have at least 24VDC on your telephone line and the phone should work properly. |
| |
| |
| |